Talk
Say the builder, subdivision, lot and block, e.g. “CBH Homes, lot 12, block 4, Valley subdivision.”
1 · Job setup
Pour weather
Opens WeatherBug's 10-day forecast. Enter the low for the pour day below.
The weather check comes up when the footing pour starts.
2 · Plan photos
Add up to 6 photos of any plan pages, in any order. Picking the page type is optional; it just helps Claude.
Tip: shoot straight on, in good light. Get the footing key and title block in frame. That's where the sizes and the city come from.
How these were figured
On iPhone or iPad, Save opens the share sheet. Pick CompanyCam to add the PDF to the job, or Save to Files.
3 · Footing key
The footing schedule from the plans. Each wall run with a matching mark takes its sizes and rebar from here.
| Mark | Ftg W (in) | Ftg D (in) | Stem W (in) | Stem H (in) | Ftg bars | Ftg # | Stem bars | Stem # | Vert o.c. (in) |
|---|
4 · Walls
Wall footage, widths and heights are set on lines 1 and 2 of the takeoff sheet above. Every wall starts as 6″; tap + on line 1 to add an 8″ or wider wall.
Heights & footing sizes
| Line | Mark | Ftg D on plan (in) |
|---|
Run-by-run from the plan read
5 · Columns
Each column type is a base (the pad footing) with a pedestal on top. For a round pedestal (sonotube), tap Round and enter the diameter.
6 · Plan counts
Hold-downs (from plan callouts)
| Type | Count |
|---|
7 · Code rules & your standards
Bar by code, by city
Rebar for the whole job by jurisdiction: continuous footing bars, wall bars, verticals, garage front and hold-downs. ✓ = taken from that city or county's own code or handout (tap Source). Verify = nothing local published online, so the IRC baseline is used; call the building dept and correct the row.
| Jurisdiction | Ftg bars | Wall bars | Verts o.c. (in) | Vert type | Garage bars | Past opening (ft) | Bars per HD | HD bar (ft) | Bar # | Status |
|---|
Garage front: IRC portal frame (R602.10.6.2) needs 1 #4 top + 1 #4 bottom of the footing under the opening, lapped 15″. Hold-downs: Simpson STHD/LSTHD need one #4 bar through the strap (24″+ at corners). Seismic Category D areas: IRC R403.1.3, 1 #4 at bottom of footing, 1 #4 within 12″ of top of wall, #4 verticals 4′ o.c.
Builder standards
Builders who want their own rebar on every job, wherever it is in the valley. When the job's builder matches a row here, Bar by code uses this row instead of the city's. Hillside lots still use the hillside rules.
| Builder | Ftg bars | Wall bars | Verts o.c. (in) | Vert type | Garage bars | Past opening (ft) | Bars per HD | HD bar (ft) | Bar # | Note |
|---|
Hillside lots
On a hillside, rebar runs the full perimeter with these bars, overriding the per-plan and bar-by-code rebar, plus dowels at each footing step.
General
Defaults follow common IRC practice (anchor bolts R403.1.6, crawlspace vents R408.1). Check them against the stamped plans.